A landfill, by the nature of the wastes placed in it, will generate dangerous gases. These gases can pose serious health and safety problems for operators and the community, both during the operation of the landfill and after it has been closed, so facilities must have landfill gas monitoring and control program plans.

Monitoring data taken at landfills does not necessarily reflect the levels of contamination to which people may be exposed. However, the data usually offers some insight into general air quality, landfill gas migration, possible health hazards and conditions within the landfill itself. In general, monitoring of gases that emanate from landfills falls into the following categories:

  • Monitoring at gas wells (most common)
  • Soil gas monitoring
  • Near surface gas monitoring
  • Emissions monitoring
  • Ambient air monitoring
  • Protection of structures / enclosed spaces where methane can accumulate

Click for datasheet: RKI Landfill Gas Detection

[crumina_heading layout=”simple” heading=”detectors required” el_class=”margin_zero_imp” subheading=”fermentation room monitoring”]
[crumina_heading layout=”simple” heading=”Brewery Applications” subheading=”continuous monitoring of CO2 and O2 in beer fermentation room and bottling area” el_class=”margin_zero_imp”]

Areas of concern for high levels of Carbon Dioxide (CO2 ) in breweries include the fermentation room and bottling area. During fermentation a significant amount of CO2 is generated and depending on the setup, may be ventilated or captured for use. Any CO2 that escapes can collect in low lying areas, forming potentially hazardous pools of gas that can build up and displace Oxygen (O2). Levels of CO2 should be checked prior to workers going into the vats to clean them. Being odourless and colourless, the presence of CO2 is not known until symptoms of exposure are experienced, unless gas detection equipment is used.

Using the QCC Quad Channel Controller with an LPT-A Analog O2 Transmitter and an AST-IS Industrial CO2 Transmitter is the solution. The placement of the two transmitters inside the fermentation room and in the bottling area provides continuous monitoring for Oxygen levels and potential leaks of Carbon Dioxide. The QCC Controller with a top mounted strobe mounted outside the room door provides a status of the air quality conditions inside the room prior to entry. If Oxygen levels fall below safety levels or if a CO2 leak is detected the top mounted strobe will activate and an audible alarm will sound. The designated relays will activate a preset response, such as turning on a remote alarm device,
actuating the mechanical ventilation system and/or triggering another set response as required.

Click for datasheet: Brewery